Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 202
Filtrar
1.
Biomater Investig Dent ; 11: 40308, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38645925

RESUMO

Harnessing the power of light and its photonic energy is a powerful tool in biomedical applications. Its use ranges from biomaterials processing and fabrication of polymers to diagnostics and therapeutics. Dental light curable materials have evolved over several decades and now offer very fast (≤ 10 s) and reliable polymerization through depth (4-6 mm thick). This has been achieved by developments on two fronts: (1) chemistries with more efficient light absorption characteristics (camphorquinone [CQ], ~30 L mol-1 cm1 [ʎmax 470 nm]; monoacylphosphine oxides [MAPO], ~800 L mol-1 cm-1 [ʎmax 385 nm]; bisacylphosphine oxide [BAPO], ~1,000 L mol-1 cm-1 [ʎmax 385 nm]) as well mechanistically efficient and prolonged radical generation processes during and after light irradiation, and; (2) introducing light curing technologies (light emitting diodes [LEDs] and less common lasers) with higher powers (≤ 2 W), better spectral range using multiple diodes (short: 390-405 nm; intermediate: 410-450 nm; and long: 450-480 nm), and better spatial power distribution (i.e. homogenous irradiance). However, adequate cure of materials falls short for several reasons, including improper selection of materials and lights, limitations in the chemistry of the materials, and limitations in delivering light through depth. Photonic energy has further applications in dentistry which include transillumination for diagnostics, and therapeutic applications that include photodynamic therapy, photobiomodulation, and photodisinfection. Light interactions with materials and biological tissues are complex and it is important to understand the advantages and limitations of these interactions for successful treatment outcomes. This article highlights the advent of photonic technologies in dentistry, its applications, the advantages and limitations, and possible future developments.

3.
Artigo em Inglês | MEDLINE | ID: mdl-38307221

RESUMO

STUDY OBJECTIVE: Anatomic anomalies of the female reproductive genital tract affect approximately 5.5% of women [1]. The hemiuterus or class U4 by the European Society of Human Reproduction and Embryology / European Society for Gynaecological Endoscopy 2013 classification is a rare congenital malformation defined as a unilateral uterine development, with a contralateral part that could be either incompletely formed or absent. This class is divided into 2 subclasses depending on the presence or not of a functional rudimentary cavity (U4a/U4b) [2]. This work aimed to share our experience performing an hysteroscopic and laparoscopic combined technique to surgically manage this uterine malformation exploiting the hysteroscopic transillumination. DESIGN: A step-by-step explanation of surgical technique with narrated video footage. SETTING: Tertiary Level Academic Hospital "IRCCS Azienda Ospedaliero - Universitaria di Bologna" Bologna, Italy. INTERVENTIONS: A 32-year-old woman with a symptomatic (severe dysmenorrhea and chronic pelvic pain) suspected U4a uterine malformation diagnosed at our center was scheduled for laparoscopic removal of the right uterine horn and ipsilateral salpingectomy exploiting the contemporary hysteroscopic transillumination guidance. We selected this approach to avoid possible complications owing to the anatomic anomalies that are very common in these cases [3,4]. After coagulation and section of the right round ligament at the uterine angle and opening of the right broad ligament, access to the retroperitoneum was obtained to directly visualize the entire course of ureter and the uterine artery. The right uterine artery was coagulated and sectioned at the uterus. Then, the hysteroscope was introduced to the uterine fundus and the light source brightness was increased up to 100% to allow an adequate transmural visualization of the uterine defect from the laparoscope. Once the defect edge was well highlighted, the right uterine horn was isolated and removed using a monopolar hook, taking care to preserve an adequate amount of myometrium. A double layer running suture with barbed absorbable thread (V-Loc) for reconstructive purposes was performed. The specimen was retrieved inside an endobag to allow a safe extraction. Right salpingectomy was then performed. CONCLUSION: Considering the great anatomic variability of this condition, this type of surgery is not always simple. Indeed, the borders between the uterus and the rudimentary uterine horn are often not perfectly recognizable; this can lead to accidental removal of healthy myometrium and increase the risk of perioperative bleeding [5]. In our experience, the combined hysteroscopic and laparoscopic combined technique allows the surgeon to better delimit the borders of the hemiuterus, providing a more conservative and safer surgery. Hysteroscopic transillumination offers the possibility to modulate the radicality in the resection of the rudimentary horn and in the final treatment of dysmorphism. VIDEO ABSTRACT.

4.
Echocardiography ; 41(1): e15739, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38284678

RESUMO

Bicuspid aortic valve is the most common congenital heart defect. Transthoracic echocardiogram is the initial tool to assess and diagnose this condition, however, transesophageal echocardiogram with 3D modalities, including transillumination have a better anatomical and functional evaluation of the valve, allowing to classify the bicuspid aortic valve according to the position of the raphe and assess the main vessels for complications or exclude other cardiovascular diseases.


Assuntos
Doença da Válvula Aórtica Bicúspide , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/anormalidades , Transiluminação , Ecocardiografia , Ecocardiografia Transesofagiana
5.
Eur J Clin Invest ; 54(2): e14103, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37815038

RESUMO

BACKGROUND: Despite the availability of current antibiotic and surgical treatment options, infective endocarditis (IE) remains associated with a high mortality rate. Even though two-dimensional (2D) transesophageal echocardiography (TOE) is a major criteria in the diagnosis of IE, it is constrained by the single-plane orientation. Since three-dimensional (3D) TOE provides a comprehensive understanding of the cardiac architecture by allowing for a realistic visualization of the underlying structures in 3D space, it has attracted considerable interest in recent years. AIM: The purpose of this narrative review is to discuss the advantages and pitfalls of 3D TOE in patients with IE, as well as to address emerging photo-realistic 3D techniques that have the potential to enhance the visualization of cardiac structures in this setting. RESULTS: According to recent research, 3D TOE acquisitions outperform 2D acquisitions in terms of vegetation identification accuracy and embolism risk assessment. By reporting a variety of findings that are missed with 2D TOE, but which are validated by surgical examination, 3D TOE further improves the ability to identify endocarditis complications on both native and prosthetic valves. In addition to conventional 3D TOE, future developments in 3D technology led to the development of transillumination and tissue-transparency rendering, which may improve anatomical understanding and depth perception. Due to the use of both conventional and novel 3D techniques, there are more patients who require surgical intervention, indicating that 3D TOE may have a clinical relevance on the surgical management. CONCLUSION: 3D TOE might fill the gaps left by 2D TOE in the diagnosis of IE.


Assuntos
Ecocardiografia Tridimensional , Endocardite , Humanos , Ecocardiografia Transesofagiana/métodos , Ecocardiografia/métodos , Endocardite/diagnóstico por imagem , Endocardite/complicações , Ecocardiografia Tridimensional/métodos , Medição de Risco
6.
J Endod ; 50(1): 22-30, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37839772

RESUMO

INTRODUCTION: The efficacy and safety of a single novel electronic pulp sensitivity tester with a transilluminator (PSTT) capable of providing 4 different tests was compared with gold standard (GS) pulp testing methods. METHODS: Four hundred eighty teeth, including 3 from each quadrant and their contralateral and opposing teeth, were randomly assessed using the PSTT or GS methods. Seven days later, the same teeth were assessed using the method not used earlier so that all teeth were evaluated using both methods. Sixty previously root canal-treated teeth, serving as negative controls, were assessed identically to the experimental groups. Results were analyzed using IBM SPSS software (IBM Corp, Armonk, NY) (P < .05). RESULTS: A higher percentage of teeth responded to cold and electricity using GS methods compared with the PSTT (99.4 vs 93.1 and 99.6 vs 97.3, respectively). A lower percentage of teeth responded to heat using the GS method compared with the PSTT (50.0 vs 68.1). Chi-square tests determined differences in the proportion of sensitivity to temperature, and electric testing methods were statistically significant (P < .001 and P = .004, respectively). No difference in the proportion of sensitivity was observed for transillumination. The Wilcoxon signed rank test determined significantly shorter cold testing times using the GS method (P = .024). Shorter testing times were observed using the PSTT for heat (P < .001), electric pulp testing (P = .048), and transillumination (P = .001). The overall PSTT testing time was significantly shorter than the GS testing time (P = .03). Tissue injury was not observed. CONCLUSIONS: The PSTT efficiently and safely provided heat and transillumination for pulpal diagnosis. Improvements are needed to enhance the cold and electric stimulus efficacy.


Assuntos
Teste da Polpa Dentária , Polpa Dentária , Estudos Cross-Over , Teste da Polpa Dentária/métodos , Temperatura , Temperatura Baixa
7.
Diagnostics (Basel) ; 13(24)2023 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-38132233

RESUMO

Dental caries remains a significant global health issue. It was highlighted by the World Health Organization's 2022 reports that despite the efforts and scientific advancements in caries detection and management, the situation has only marginally improved over the past three decades. The persistence of this problem may be linked to outdated concepts developed almost a century ago but are still guiding dentists' approach to caries management today. There is a need to reconsider professional strategies for preventing and managing the disease. Contemporary dentistry could benefit from embracing new concepts and technologies for caries detection and management. Dentists should explore, among others, alternative methods for caries detection such as optical-based caries detection. These tools have been established for over a decade and they align with current disease understanding and international recommendations, emphasizing early detection and minimally invasive management. This narrative review presents the current state of knowledge and recent trends in caries detection, diagnosis, monitoring, and management, offering insights into future perspectives for clinical applications and research topics.

8.
Rev. enferm. UERJ ; 31: e74664, jan. -dez. 2023.
Artigo em Inglês, Português | LILACS-Express | LILACS | ID: biblio-1525066

RESUMO

Objetivo: avaliar o índice de sucesso na primeira tentativa de cateterização intravenosa periférica em crianças após capacitação de profissionais de enfermagem para o uso de transiluminação. Método: estudo observacional, prospectivo, comparativo do tipo antes e depois, realizado com enfermeiros e técnicos de enfermagem que foram capacitados para a cateterização guiada pela transiluminação e observados executando 35 procedimentos antes e 35 após a capacitação, no período de novembro de 2018 a maio de 2019, após aprovação do mérito ético do protocolo de pesquisa. Os dados foram analisados de forma descritiva e analítica. Resultados: o índice de sucesso na primeira tentativa foi de 62,9% antes e 65,7% depois (p=0,803). Os técnicos de enfermagem executaram mais a punção antes da capacitação e os enfermeiros depois (p<0,01). Conclusão: a capacitação de profissionais para realizar a punção guiada pela transiluminação aumentou o índice de sucesso na primeira tentativa de punção intravenosa periférica, sem diferença estastiticamente significativa.


Objective: to evaluate the puncture success in the first attempt in children after training nursing professionals in the use of transillumination. Method: observational, prospective, comparative before-and-after study, carried out with nurses and nursing technicians were trained for transillumination-guided catheterization and observed performing 35 procedures before and 35 after training, from November 2018 to May 2019, after approval of the ethical merit of the research. Data were analyzed descriptively and analytically. Results: success in the first attempt was 62.9% before and 65.7% after (p=0.803). Nursing technicians performed more punctures before training and nurses after (p<0.01). Conclusion: the training professionals to perform transillumination-guided puncture increased success in the first attempt at peripheral intravenous puncture, without significant statistical difference.


Objetivo: evaluar la tasa de éxito en el primer intento de cateterización venosa periférica en niños después de capacitar a los profesionales de enfermería en el uso de la transiluminación. Método: estudio observacional, prospectivo, comparativo de antes y después, realizado junto a enfermeros y técnicos de enfermería capacitados para cateterización guiada por transiluminación y observados realizando 35 procedimientos antes y 35 después del entrenamiento, de noviembre de 2018 a mayo de 2019, previa aprobación del mérito ético del protocolo de la investigación. Los datos se analizaron de forma descriptiva y analítica. Resultados: la tasa de éxito en el primer intento fue del 62,9% antes y del 65,7% después (p=0,803). Los técnicos de enfermería realizaron más punciones antes del entrenamiento y los enfermeros después (p<0,01). Conclusión: la formación de profesionales para realizar la punción guiada por transiluminación aumentó la tasa de éxito en el primer intento de punción venosa periférica, sin diferencia estadística significativa.

9.
Biology (Basel) ; 12(11)2023 Oct 24.
Artigo em Inglês | MEDLINE | ID: mdl-37997961

RESUMO

The classical transillumination technique has been revitalized through recent advancements in optical technology, enhancing its applicability in the realm of biomedical research. With a new perspective on near-axis scattered light, we have harnessed near-infrared (NIR) light to visualize intricate internal light-absorbing structures within animal bodies. By leveraging the principle of differentiation, we have extended the applicability of the Beer-Lambert law even in cases of scattering-dominant media, such as animal body tissues. This approach facilitates the visualization of dynamic physiological changes occurring within animal bodies, thereby enabling noninvasive, real-time imaging of macroscopic functionality in vivo. An important challenge inherent to transillumination imaging lies in the image blur caused by pronounced light scattering within body tissues. By extracting near-axis scattered components from the predominant diffusely scattered light, we have achieved cross-sectional imaging of animal bodies. Furthermore, we have introduced software-based techniques encompassing deconvolution using the point spread function and the application of deep learning principles to counteract the scattering effect. Finally, transillumination imaging has been elevated from two-dimensional to three-dimensional imaging. The effectiveness and applicability of these proposed techniques have been validated through comprehensive simulations and experiments involving human and animal subjects. As demonstrated through these studies, transillumination imaging coupled with emerging technologies offers a promising avenue for future biomedical applications.

10.
Anesth Pain Med (Seoul) ; 18(4): 431-438, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37919927

RESUMO

BACKGROUND: Traditionally, the patient's head is placed in a neutral position with a chin-lift to facilitate light wand guided endotracheal intubation. However, our study found that the sniffing position was more effective. In this study, we aimed to compare the two positions of light wand guided endotracheal intubation. METHODS: Sixty adult patients were included in the study, after obtaining informed consent, and were randomly assigned to one of two groups: a control group in a neutral position with a chin-lift (group C, n = 30) and a sniffing position group (group S, n = 30). In group C, the anesthesiologist inserted a light wand after lifting the patient's mandible using the thumb of their non-dominant hand inside the patient's mouth. In group S, a light wand was inserted after the patient's head was flexed with the neck extended. We assessed variables such as light-search time, number of intubation attempts, time to achieve intubation, and side effects including blood tinge on the endotracheal tube, hoarseness, sore throat, and anesthesiologist satisfaction. RESULTS: The light-search and intubation times were shorter in group S than in group C. The incidence of blood tinge on the endotracheal tube was higher in group C than in group S. Anesthesiologist satisfaction was higher in group S than in group C. CONCLUSIONS: The sniffing position was more effective in facilitating light wand guided endotracheal intubation than the neutral position with a chin-lift.

11.
Cureus ; 15(10): e47426, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38022122

RESUMO

We report a case of bilateral acute iris transillumination (BAIT) syndrome caused by an overdose of oral moxifloxacin in a Hispanic female patient with no previous respiratory viral infection. A 56-year-old Hispanic female with no history of ocular illness was referred to our glaucoma service to manage her microcystic edema, swelling, and refractory ocular hypertension. Her ocular and systemic symptoms, including progressively worsening bilateral ocular pain, severe photophobia, blurred vision, nausea, and vomiting, started 14 days after an accidental overdose of oral moxifloxacin. Moxifloxacin had been prescribed to treat a complicated urinary tract infection. A slit-lamp examination revealed bilateral microcystic corneal edema and transillumination in the right temporal iris, both consistent with a diagnosis of BAIT syndrome. The existing literature on BAIT syndrome is scarce, and its etiology remains unclear. This case provides clinical evidence supporting moxifloxacin toxicity as a possible cause of BAIT syndrome. We emphasize the importance of conducting extensive research to define the mechanisms involved in moxifloxacin-induced BAIT syndrome and to search for other potential etiologies of this condition.

12.
Diagnostics (Basel) ; 13(20)2023 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-37892078

RESUMO

This in vitro study aimed to investigate the diagnostic potential of short-wave infrared transillumination (SWIRT) at 1050, 1200 and 1300 nm for the detection of proximal caries in molars and premolars. It was compared to the diagnostic performance of bitewing radiography (BWR) and micro-computed tomography (µCT) as the reference standard. 250 sound or decayed proximal surfaces of permanent posterior extracted teeth were examined using (1) SWIRT at 1050, 1200 and 1300 nm with two camera systems of different resolutions, (2) BWR and (3) µCT. Thresholds were defined for both test methods and the reference standard for caries in general, enamel caries and dentin caries. All images were assessed by two examiners twice, at an interval of two weeks. SWIRT at wavelengths of 1050, 1200 and 1300 nm achieved sensitivity values more than 2.5 times higher than BWR (enamel caries 3.2-4.4 times; dentin caries 3.25-4.25 times) for the detection of proximal caries. Sensitivity values of SWIRT improved with the higher wavelength. No significant difference was found in diagnostic quality between the two camera systems. SWIRT at 1300 nm imaged proximal enamel caries with the highest accuracy, while the physical optimum for transillumination in dentin was located at a lower wavelength (<1000 nm).

13.
Cureus ; 15(9): e44558, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37790023

RESUMO

The purpose of this article is to report a case of bilateral foveal hypoplasia in an eight-year-old girl who presented to the ophthalmology department due to poor vision in both eyes. Clinical examination revealed bilateral nystagmus, decreased vision, as well as iris transillumination. Dilated fundus examination indicated the absence of light reflex around the foveal area and optical coherence tomography (OCT) imaging exhibited the absence of the fovea centralis depression. These findings, in addition to the patient's light-colored hair and skin complexion, raised suspicion for albinism. The patient was referred for genetic testing and the results confirmed the diagnosis of tyrosinase-positive oculocutaneous albinism (OCA2).

15.
Am J Ophthalmol Case Rep ; 32: 101912, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37680309

RESUMO

Purpose: To report a patient with a unilateral presentation of glaucoma, pain, and acute iris transillumination syndrome simulating iris melanoma. Observations: A 53-year-old male presented with blurred vision and pain in his right eye several weeks following a respiratory sinus infection managed by oral azithromycin. Examination of the right eye was notable for elevated intraocular pressure of 46 mm Hg, an irregular mid-dilated pupil, and diffuse iris transillumination with pigmentary seeding on the iris surface, in the anterior chamber angle, and on the sclera, suspicious for diffuse iris melanoma with glaucoma and extrascleral extension. Ultrasound biomicroscopy (UBM) of the right eye revealed circumferential anterior chamber angle and trabecular meshwork involvement by an infiltrative process corresponding to the pigmented cells noted clinically, while the ciliary body was unremarkable. Following enucleation, histopathology showed extensive necrosis of the iris pigment epithelium, sphincter, and dilator muscles with melanophagic infiltration in the anterior chamber angle and episclera, mild chronic non-granulomatous iridocyclitis, and no evidence of a melanocytic neoplasm. Although immunohistochemical studies for herpes simplex virus (HSV) types 1 and 2, varicella-zoster virus, and cytomegalovirus were negative, qualitative real-time polymerase chain reaction on paraffin-embedded tissue detected HSV-1 DNA. The combined clinical, pathologic, and molecular findings were compatible with unilateral acute iris transillumination syndrome, likely HSV-1 associated. Conclusion and Importance: Unilateral acute iris transillumination syndrome with diffuse iris pigment epithelial loss can simulate iris melanoma. Prompt herpes viral studies may be informative.

16.
Diagnostics (Basel) ; 13(17)2023 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-37685362

RESUMO

The aim of this clinical study was to compare the diagnostic performance of dual short wavelength infrared (SWIR) occlusal transillumination and reflectance multispectral imaging with conventional visual assessment and radiography for caries detection on premolars scheduled for extraction for orthodontics reasons. Polarized light microscopy (PLM) and micro-computed tomography (microCT) performed after tooth extraction were used as gold standards. The custom-fabricated imaging probe was 3D-printed and the imaging system employed a SWIR camera and fiber-optic light sources emitting light at 1300 nm for occlusal transillumination and 1600 nm for reflectance measurements. Teeth (n = 135) on 40 test subjects were imaged in vivo using the SWIR imaging prototype in the study and teeth were extracted after imaging. Our study demonstrates for the first time that near-simultaneous real-time transillumination and reflectance video can be successfully acquired for caries detection. Both SWIR imaging modalities had markedly higher sensitivity for lesions on proximal and occlusal surfaces compared to conventional methods (visual and radiographic). Reflectance imaging at 1600 nm had higher sensitivity and specificity than transillumination at 1300 nm. The combined SWIR methods yielded higher specificity but the combined sensitivity was lower than for each individual method.

17.
Int J Surg Case Rep ; 110: 108642, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37651806

RESUMO

INTRODUCTION: Encephalocele is defined as the externalization of brain tissue and/or meninges from the skull through a congenital bony defect. It is one of the most severe neural tube defects. CASE PRESENTATION: We report a female newborn, weighing 2800 g, APGAR score 8/10. At birth, the clinical examination revealed a weight of 2800 g, a head circumference of 33 cm with a non bulging anterior fontanel. DISCUSSION: Prenatal diagnosis of encephalocele is made by maternal screening of serum alpha-fetoprotein levels and by ultrasound. On two-dimensional ultrasound, encephalocele appears as a cystic mass with heterogeneous contents in continuity with certain brain structures. 2D ultrasound detects about 80 % of encephaloceles. The diagnosis is easily and confidently made from the ultrasound findings in the second trimester and can also be made in the first trimester. The prognosis of newborns with encephalocele depends on the extent of neural tissue herniation in the sac and the presence of associated anomalies. CONCLUSION: The purpose of this observation is to highlight the contribution of different antenatal imaging methods in the diagnosis of encephalocele.

18.
Ocul Immunol Inflamm ; : 1-6, 2023 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-37652695

RESUMO

PURPOSE: To describe the clinical and demographic characteristics and associated factors leading to bilateral acute iris transillumination (BAIT) syndrome. METHODS: A retrospective review of patients with BAIT syndrome was performed. RESULTS: Thirty-five patients with a diagnosis of BAIT were identified. The median age at presentation was 53 years; 80% of the patients were female. Twenty-six patients (74%) had recent histories of systemic antibiotic treatment. Of those with such a history, 24 patients (92%) had been receiving moxifloxacin. Two patients within our cohort were prescribed moxifloxacin prophylactically prior to a systemic surgical procedure and had no evidence of systemic illness or recent viral illness. CONCLUSIONS: Our data support the notion that moxifloxacin might be associated with the onset of BAIT syndrome. Notably, within our cohort, two patients received moxifloxacin as surgical prophylaxis and subsequently developed BAIT syndrome. This could suggest a potential association between moxifloxacin and the onset of BAIT, though further studies are needed to confirm this finding.

19.
Photodiagnosis Photodyn Ther ; 44: 103744, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37567332

RESUMO

BACKGROUND: This study compared the performance of near-infrared light transillumination (NILT; DIAGNOcam [DC]) in detecting occlusal caries lesions in deciduous molars with the performance of the International Caries Detection and Assessment System (ICDAS), digital radiographic method (RX) and laser fluorescence (DIAGNOdent pen [LFpen]). METHODS: Fifty-seven extracted deciduous molars with no frank cavitation caries lesions were selected. One site per tooth was evaluated twice each by two examiners using all methods. Then, a histological examination was performed using a stereomicroscope. The performance of the methods was assessed with respect to two thresholds: D1 (all visible caries lesions affecting enamel) and D3 (caries lesions extended into dentin). RESULTS: A weighted kappa and intraclass correlation coefficients were calculated for intra- and inter-observer reproducibilities, varying from 0.31 (RX) to 0.89 (LFpen). The intra-observer reproducibility at D1 and D3 thresholds varied from 0.51 (ICDAS) to 0.85 (DC) and from 0.30 (ICDAS) to 1.00 (RX), respectively. The inter-observer reproducibility varied from 0.28 (RX) to 0.47 (DC) and from 0.22 (LFpen) to 0.75 (DC), respectively. At the D1 threshold, higher sensitivity and accuracy were found for LFpen (0.76/0.71) and ICDAS (0.65/0.66); and higher specificities were found for RX (0.94), DC (0.79), and ICDAS (0.71). At the D3 threshold, all methods exhibited lower sensitivities (0.13-0.35) and higher specificity, accuracy, and area under the ROC curve values (0.70-1.00). All methods showed a correlation with histological results, especially for ICDAS and DC. CONCLUSIONS: NILT technology (DC) and LFpen exhibited similar performance for the detection of occlusal caries lesions in deciduous molars when compared with ICDAS criteria.


Assuntos
Cárie Dentária , Fotoquimioterapia , Humanos , Sensibilidade e Especificidade , Transiluminação , Reprodutibilidade dos Testes , Suscetibilidade à Cárie Dentária , Fluorescência , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes , Dente Decíduo , Cárie Dentária/diagnóstico por imagem , Cárie Dentária/patologia
20.
Vet Rec ; 192(12): e2881, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37004214

RESUMO

BACKGROUND: Arterial access in small-breed dogs is challenging, but arterial visualisation may facilitate the procedure, as evidenced in human medicine. This prospective, randomised study investigated the result of using transillumination to guide coccygeal artery cannulation in small-breed dogs. METHODS: Coccygeal artery cannulation was attempted in dogs anaesthetised with butorphanol, midazolam, propofol and sevoflurane. In 70 dogs (standard technique group [STECHNIQUE group]), arterial cannulation was performed using pulse palpation. In 71 dogs (transilluminating-standard technique group [TSTECHNIQUE group]), a transilluminating device was utilised. The device was placed on the dorsal tail, and the cannula was advanced towards the dark line visible against the bright background. If the artery was not well visualised due to pigmentation, pulse palpation was used. The success rate of arterial cannulation was compared between the groups using the chi-squared test. RESULTS: Arterial cannulation was significantly more successful (p < 0.001) in the TSTECHNIQUE group (63/71 [88.7%]) than in the STECHNIQUE group (43/70 [61.4%]). LIMITATIONS: The number of punctures attempted and the time to cannulation were not assessed, and the procedure was only performed by veterinarians experienced in arterial cannulation. CONCLUSIONS: The transillumination allows for a more accurate approach to the coccygeal artery, improving the success of arterial cannulation when combined with pulse palpation.


Assuntos
Cateterismo Periférico , Animais , Cães , Cateterismo Periférico/veterinária , Cateterismo Periférico/métodos , Estudos Prospectivos , Artéria Radial/diagnóstico por imagem , Transiluminação/veterinária , Ultrassonografia de Intervenção/veterinária
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...